Search results for "Single lead"
showing 5 items of 5 documents
Paroxysmal atrial fibrillation and high degree AV block: use of single-lead VDDR pacing with mode switching.
1998
Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of…
A simple method for preoperative assessment of the best fitting electrode length in single lead VDD pacing.
1996
For single lead VDD pacing, electrodes with various distances between the lead tip and the floating atrial dipole (AV distance) are available. Using different AV distances allows positioning of the atrial dipole in the mid- to high right atrium, regardless of the size of the right heart. In this position, reliable atrial sensing and rejection of ventricular far-field potentials can be expected. A simple test for the preoperative assessment of the best fitting AV distance in the individual patient was tested. We studied 24 consecutive patients prior to implantation of a VDD pacemaker. With the patient in supine position, a test electrode with an AV distance of 13 cm was taped onto the thorax…
Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?
1998
UNLABELLED In single-lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far-field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. METHODS The study included 10 patients with a single-lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak-to-peak amplitudes of P…
Cardiac output in single-lead VDD pacing versus rate-matched VVIR pacing.
1995
The importance of atrioventricular synchronous pacing compared with single-chamber rate-responsive pacing is still under discussion, especially for low-intensity workload representing daily life activities. We evaluated hemodynamics in single-lead VDD pacing versus VVIR pacing in 11 patients (8 men and 3 women, aged 58.6 +/- 13.8 years) with normal left ventricular function and a previously implanted single-lead VDDR pacemaker. A low-intensity steady-state treadmill test at 1 to 2.5 mph with a gradient of 2% to 4% was performed. Cardiac output was determined using a standard carbon dioxide rebreathing technique. Initially, the VDD mode was programmed, and after 5 minutes of exercise, cardia…
Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers
2002
WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …